COMBILOG• Logbox-AA is a dual channel universal input data logger which   directly accepts several analog industrial signals and sensors   as voltage, current, thermocouples and RTDs.

• This self-operated logger is extremely flexible and can be   easily programmed and set via a handy infrared IR-LINK 3   interface connected to a USB port under Windows software or   with a Palm compatible PDA IrDA interface under PalmOS.
                         
• LogChart II software allows for logger configuration, recorded   data retrieval, plotting and historical analysis and exports data   to spread sheets.

• Its sturdy water proof enclosure provides full performance in                                                                the most demanding applications.

 

 

LogChart II software allows for logger configuration,recorded data retrieval, plotting and historical analysis and exports data to spread sheets.

Infrared communication to a PC is achieved by using the IrLink 3 interface connected to a USB port (RS232 is optional).

Configuration, data retrieval and analysis can be also done by using a convenient Palm OS compatible PDA through its IrDA interface. This reduces cost and dramatically increases portability.

Data downloaded from multiple LogBox units to a Palm can be later transferred and syncronized to a PC by means of the native Palm sync tool.

Once the data are transferred to a PC they can then be better visualized and exported by the LogChart II software .

For more information or to make an enquiry please contact us.

Product Specification

Inputs Dual universal multi-sensor inputs, individually programmable for Pt100, Thermocouples (types J, K, T, E, N, R, S or B), voltage (0 to 50 mV or 0 to 10 V), or current (0 to 20 mA or 4 to 20 mA)
Accuracy 0.2% of full scale for Pt100, current and voltage; 0.25% of full scale ±3ºC for t/cs type R,S and B; 0.25% of full scale ±1ºC for all other thermocouples
Input resolution 14 bits
Launch options immediate, programmed time and date, or via Palm
Stop options when full, at a certain time, after a number of readings, or wrap around (overwrites first readings)
Memory 32,000 recordings in one channel or 16,000 recordings for each channel
Recording interval programmable from 1 s to 18 hours
Battery Internal replaceable lithium cell (3.6V ½ AA)
Estimated battery life 1 year with one daily download and 5 min measuring interval. Battery life depends heavily on data retrieval frequency
Operating temperature -40°C to 70°C
Dimensions 70 x 60 x 35 mm

 